1. amp 5V power cables and SATA cables to iR2620 SR2611 2 Connect SATA cable to SATA port on the motherboard rf 0 Internal RS232 Cable External RS232 Cable I SATA Cable Power Supply Connector Power Supply iIR2620 SR2611 PL GND sv aw O a o e o000 E Motherboard SATA Ports Internal Case SR2611 Real Panel A Note 1 RS232 Port and RS232 Cable Provides hardware status monitoring to industrial control system or IPC via RS232 If more information required please contact at supporting raidon com tw Connecting iR2620 SR2611 to your computer 7 www RAIDON com tw RAIDON 2 We do not recommend users to disassemble the device without proper instructions and authorization The manufacture warranty will not cover the damages caused by unauthorized disassembling 3 To prevent the device from malfunction please make sure the device is connected with a direct and dedicated power connection of a stable power input Chapter 6 Setting the Hard Drive Array Mode Please select the RAID mode with the jumper located at the back panel The original default is RAID 1 still there are three pins at the back panel for RAID mode selection RAID 0 mode by setting the jumper on the bottom of the two pins RAID 1 mode by setting the jumper on the top of the two pins 1 RAID 0 Mod
2. D of Sec HDD LED of Pri HDD LED of Sec HDD Mute Button LED of Pri HDD Mute Button Key Lock LED of Sec HDD Key Lock iIR2620 Real Panel SR2611 Real Panel olll o iiS 0 0 E oW o I o Jil oji o A RAID Mode Fan RAID Mode RS232 Port SATA Port RS232 Port SATA Port 4 Pin Big Power Connector 4 Pin Big Power Connector A note 1 Status Indications of LEDs 1 iR2620 A LED of Pri Sec HDD which near LCD display will flash yellow when the data is accessed from the hard drive B LED of Pri Sec HDD on the HDD tray will flash blue when the data is accessed from the hard drive C LED of failure alarm will light red when HD failed temperature is higher than 60 C or fan fails 4 Hardware Introduction www RAIDON com tw RAIDON 2 SR2611 A LED of Pri Sec HDD will flash yellow when the data is accessed from the hard drive B LED of failure alarm will light red when HD failed temperature is higher than 60 C or fan fails 2 Mute Button Press to turn on mute function to shut off the buzzer alarm just press the bottom again Chapter 3 Precaution before Usage 1 Hardware Requirement 1 Computers or servers with SATA I amp SATA II 2 Hard drive with SATA I amp SATA II Notices 1 iIR2620 SR2611 s brilliant design allows the user to simultaneously utilize two hard drives manu factured by differ
3. RAIDON InTANK Series IR2620 2S S2 SR2611 2S S2R User Manual IR2620 2S S2 SR2611 2S S2R v 2 2 Jun 2011 www RAIDON com tw RAIDON Index Chapter 1 Check Package Contents and Accessories Chapter 2 Hardware Introduction Chapter 3 Precaution before Usage Chapter 4 Hardware Installation Procedure Chapter 5 Connecting iR2620 SR2611 to your computer Chapter 6 Setting the Hard Drive Array Mode Chapter 7 Computer Set Up Chapter 8 Hard Disk status on LCD screen Chapter 9 Data Rebuilding Operation Chapter 10 GUI Monitoring Software amp FW Updating Appendix Trouble Shooting Q amp A www RAIDON com tw RAIDON Chapter 1 Check Package Contents and Accessories IR2620 SR2611 system includes the following Item Quantity Accessory bag iR2620 includes 6 of screws for device 6 of screws for HDD tray and 2 of keys for key lock SR2611 includes 8 of screws and 2 of keys for key lock iR2620 Internal RS232 Cable External RS232 Cable SATA Cable Accessory bag CD A Note Please check above parts are included prior to installation The accessory bag contains screws and a plastic key Check Package Contents and Accessories 3 www RAIDON com tw RAIDON Chapter 2 Hardware Introduction iIR2620 Front Panel SR2611 Front Panel 2 Tray of Pri HDD Tray of Sec HDD tar O LCD Display LED of Failure Alarm LCD Display LED of Failure Alarm LED of Pri HDD LE
4. ay screen will display Wrong Capacity The LCD display screen might display rebuilding error messages such as Pri s gt Sec s or Sec s gt Pri s The term s signifies that both hard drives are treated as original hard drive The user must determine which hard drive will be the original hard drive prior installing the hard drives into iR2620 SR2611 Once the original hard drive is designated and installed in iR2620 SR2611 the user can place in the second hard drive by taking advantage of iR2620 SR2611 s Auto Rebuilding function 16 Appendix Trouble Shooting Q amp A www RAIDON com tw RAIDON Q My hard drive is obviously operating properly but why is it shown as failed in the IR2620 SR2611 display A iR2620 SR2611 uses more strict requirements and standards to examine the bad sectors in the hard drive The user can first overwrite the bad sector on a PC before placing the hard drive into iIR2620 SR2611 About Auto Rebuilding Function Q What will happen if we turn off the computer s power while iR2620 SR2611 is still executing data auto rebuilding A Under the mirror mode RAID 1 if the power is out of the auto rebuilding process the controller will remember when completion percentage of the auto rebuilding process and resume the rebuilding process when the power is back on Is it possible to lose any part of the data during the data auto rebuilding The data auto rebuilding function will cop
5. bol is displayed this means that there is a cooling fan failure If the T symbol is displayed this means that the system is overheated Appendix Trouble Shooting Q amp A 17 www RAIDON com tw RAIDON Q How to turn on and off the Buzzer A 1 The manufacture default setting for the Buzzer in iR2620 SR2611 is Buzzer On 2 The user can use any pointed materials to push the bottom on the front dash board to turn on and off the Buzzer NOTE RAIDON Technology Inc provides both technical support and service to our global distributor and as for the end users or do not buy products directly from us please contact where your purchase from or local distributor for prompt and better responses service However if you do not know the local distribu tor s location please contact RAIDON sales1 raidon com tw for reference All the product information contained in this manual is the property of RAIDON Technology Inc All rights reserved 18 Copyright declaration www RAIDON com tw
6. e 1 Place two new hard drives into iR2620 SR2611 and strongly suggest you to use two identical hard drives to get the equal capacity If the capacity is different iIR2620 SR2611 is downward to the small hard drive capacity 2 Under RAID 0 mode capacity is add up to a one big volume also with the feature of faster read write performance efficient 2 RAID 1 Mode 1 Place two new hard drives into iR2620 SR2611 and strongly suggest you to use two identical hard drives to get the equal capacity If the capacity is different iIR2620 SR2611 is downward to the small hard drive capacity 2 Under RAID 1 mode two hard drives has the identical information as one to mirror to the other one therefore each of the hard drive failed is still able to function normally When you replace the failed hard disk to the new one the system automatically rebuilding the data to the newly place hard disk 8 Setting the Hard Drive Array Mode www RAIDON com tw RAIDON Chapter 7 Computer Set Up When the hardware setup for iR2620 SR2611 is complete you are now ready to turn the machine on 1 After the hardware installation is complete the iIR2620 SR2611 will be treated as one single hard drive Set the hard drive to AUTO in the computer s BIOS When the computer is turned on the system will retrieve the following information 2 In iR2620 SR2611 the installed hard drive can be detected by the Device Manager of Computer Management
7. echnical support department Q When the iR2620 SR2611 is in use the computer system is functioning normally but the IR2620 SR2611 access speed is abnormal A Please first check whether the iR2620 SR2611 is in the progress of executing data auto rebuild 1 Please examine if the length of the connection cables SATA cable that connect the drives to the computer system is too long and whether the specification these cables complies with the requirements 2 If both the lengths and specification of the cables are checked out ok please turn off IR2620 SR2611 and remove the hard drive from iR2620 SR2611 Test the hard drive directly with the computer system since it might be the bad sectors in the hard drive that are causing the longer than normal system down time Hard Drive Failure Q Under the mirror mode RAID 1 what will be the system s total storage capacity when adding a brand new hard drive A 1 The total storage capacity for iIR2620 SR2611 is determined by the storage capacity of the primary hard drive installed during the initial usage 2 The storage capacity will not increase after initial installation even when place a brand new hard drive with larger storage capacity Q Why does the error message appear when installed the second hard drive A 1 The storage capacity of the second hard drive must be larger than the first hard drive Otherwise iR2620 SR2611 can not rebuild the new hard drive and the LCD displ
8. ent companies However if the user expects better efficiency we strongly recommend the users to use hard drives manufactured by the same manufacturer 2 The iR2620 SR2611 had undergone strict hard drive compatibility test The result shows that it is compatible with most hard drives on the market such as Western Digital Seagate Fujitsu Hitachi and etc However due to the new types of hard drives appearing on the market if your hard drive is not compatible with the system please contact us through the following email supporting raidon com tw and we will reply as soon as possible 3 The iR2620 SR2611 is equipped with a ball bearing cooling fan that will provide effective cooling for the 7200 amp 10000 rpm hard drive We highly recommend using computer chassis with effective cooling design to avoid disk array crashing due to ineffective cooling 4 iR2620 SR2611 supports RAID 0 amp RAID 1 Precaution before Usage 5 www RAIDON com tw RAIDON Chapter 4 Hardware Installation Procedure 1 Install your hard disks into the removable trays and secure them with the screws from accessory kit This will protect your hard disk from any unnecessary movement iIR2620 SR261 1 2 Once the hard disks have been installed insert the removable trays into device and close the handles 6 Hardware Installation Procedure www RAIDON com tw RAIDON Chapter 5 Connecting iR2620 SR2611 to your computer 1 Connect DC12V
9. for Windows 3 Customers can choose to format the hard drive by using the Disk Management tool of the operating system before using the iR2620 SR2611 g Computer Management Fie Action view Window Help e Am e AXES caR Computer Management Local volume Layout Type File System El B System Tools SJ C Partition Basic NTFS Healthy System 29 29GB 11 28 GB 38 i fa Event Viewer 6 D Partition Basic NTFS Healthy Boot 7 97GB 5 15 GB 64 ga Shared Folders N Partition Basic NTFS Healthy 74 53GB 74 46GB 99 F Local Users and Groups ie Performance Logs and Alerts Device Manager E amp Storage g Removable Storage ae Disk Defragmente E E Services and Applications Services rete T 79 a8 wet contre F 29 29 GB NTFS GB NTFS H E Indexing Service Healthy System Healthy Boot CD ROM E f ci New Yolume F A Vj 74 53 GB NTFS 4 Mealy Z E Primary partition At this point the installation process is completely finished The user can freely retrieve and save data to iR2620 SR2611 just like retrieving and saving data to a regular hard drive If the user experiences any abnormality during the operation please refer to the trouble shooting Q amp A section in Appendix Computer Set Up 9 www RAIDON com tw RAIDON Chapter 8 Hard Disk status on LCD screen Normal hard drives Pri HDD OK Sec HDD OK Primary hard dr
10. ive is failure but secondary hard drive is normal Pri HDD Failed Sec HDD OK Primary hard drive storage capacity larger than secondary hard drive Wrong Capacity PRI gt SEC Secondary hard drive storage capacity larger than primary hard drive Wrong Capacity SEC gt PRI Rebuilding Rebuilding Rebuilding Pri gt Sec XXX Sec gt Pri XXX Overheat Pri HDD OK Sec HDD OK T Fan failure Pri HDD OK F Sec HDD OK 10 Hard Disk status on LCD screen www RAIDON com tw RAIDON Chapter 9 Data Rebuilding Operation The hard drive Hot Swap and Auto Rebuilding functions are available The Hot Swap amp Auto Rebuilding functions are applicable in 1 Off line Back up When the data is stored within iR2620 SR2611 the user can remove one of the hard drives from iR2620 SR2611 as back up drive for data such as system operation file secured files seldom modified files or image and music files The user can periodically insert the hard drive back into iR2620 SR2611 to execute automatic backup to protect the system from being hit by computer virus or to avoid risk of having both hard drives failing at the same time During the Hard drive Failure When one of the two hard drives fails in the iIR2620 SR2611 system the system will alarm the hard drive failure message both on the LCD display screen and in the monitoring software The user can remove the failed hard drive from the system
11. reen As shown in illustration Pri HDD OK Sec HDD OK T 8 When cooling fan module is not functional F will be displayed on the upper right hand corner of screen As shown in illustration Pri HDD OK F Sec HDD OK Chapter 10 GUI Monitoring Software and Firmware Update You can install GUI software to monitor RAID status This can be done by installing software from CD ROM X The HDD1 equals to Pri HDD and HDD2 equals to Sec HDD 1 RAID information This GUI will auto detects the connected iR2620 SR2611 and reveals relative information accordingly 12 GUI Monitoring Software amp FW Updating www RAIDON com tw RAIDON RAID Management Mode Mirroring RAID1 System Capacity 1863 GB HDD1 HDD2 Fimmare Upgrade E Mail Notify Capacity 1863 GB Capacity 1863 GB About WDC WD20EADS 00S2B0 WDC WD20EADS 00S2B0 Firmware Version 100624 1 C0OA 2 Firmware Upgrade You may update the Firmware via this GUI simply click on Load button to locate the firmware file to proceed After update is finished you may restart the power properly to operate with newly updated firmware RAID Management Firmware Version 100624 1 C0OA Please do not disconnect the device while updating firmware to prevent from the update failed in case the update firmware failed results in data loss we strongly suggest you backup data to other device before updating firmware You Can get newest ve
12. rsion form supporting raidon com tw A Caution Any Random firmware updates may cause device in malfunction it is strongly suggested not to update device firmware if device is operating properly To prevent device malfunctioning from your firmware updates please contact RAIDON technical support personnel for confirmation or by e mail at supporting raidon com tw GUI Monitoring Software amp FW Updating 13 www RAIDON com tw RAIDON 3 E Mail Notify Configuring an e mail address for notification of drive malfunctioning or being removed 3 1 Setup 1 Insert Outgoing SMTP and e mail name and address 2 If it is passwords required select the option SMTP Login Authentication and insert the passwords 3 When the configuration completed click on the OK button to save X Device must be connected in operational states during configurations to take effects RAID Management M Device1 oR E Mail Setu System Status a amp D gt Port 25 Default 25 Firmware Upgrade Local Information A Name Pox Time Out SMTP Login Authentication 3 2 HDD Fail Device Removed 1 Insert the e mail address of the receiver for notification and click on to add the inserted e mail address onto the notifying list Maximum up to 10 e mail addresses 2 Insert the error message and descriptions from the columns of Subject and Contents 3 When the configuration comple
13. ted click on the OK button to save X Device must be connected in operational states during configurations to take effects 14 GUI Monitoring Software amp FW Updating www RAIDON com tw RAIDON RAID Management MV Device1 l sen ioon ooo E Mail A E Mail Edit System Status melisani Finnevare Upgrade Contents Auto Add Hard Disk Fail info and system info in front of E Mail contents Detected OK 4 About Indicates GUI Management Software version RAID Management MV Device RAID Management Sofeware Version v0 23 1 Firmevare Upgrade E Mail Notify TECHNOLOGY INC Copyright 2000 2010 RAIDON Technology Inc All Rights Reserved GUI Monitoring Software amp FW Updating 15 RAIDON com tw RAIDON Appendix Trouble Shooting Q amp A Unstable system after connecting iR2620 SR2611 Q After installing iR2620 SR2611 we are unable to start the computer or the computer can not locate iR2620 SR2611 upon startup A 1 Please check whether the readings on the iR2620 SR2611 LCD display screen appear normal 2 Please check whether the SATA Cable connection cables are properly connected to the computer system and whether SATA drives are functioning normally 3 If everything is functioning properly but the user still can not start the computer system then the problem might be the system incompatibility If such incompatibility takes place please contact our t
14. while the system is still in operation without shutting down the machine If the failed hard drive is replaced shortly the system will automatically execute the Auto Rebuilding function with out affecting the system operation and without any operation command from the user The LCD Display Message During Hot Swap and Auto Rebuilding When the iR2620 SR2611 detects a hard drive missing or a hard drive failure the Buzzer will go off and the LCD display screen will display the following messages Pri HDD OK Pri HDD Failed Sec HDD Failed Sec HDD OK After removing the failed hard drive and replacing with a new hard drive if the hard drive is properly installed the LCD display screen will display the following messages Pri HDD OK Sec HDD OK 5 After few seconds of installing the new hard drive the LCD display screen will display the data rebuilding progress Rebuilding Rebuilding Pri gt Sec XXX Sec gt Pri XXX Pri gt Sec represents that the data in the original hard drive primary hard drive is copied to the new hard drive Secondary hard drive XXX represents the rebuilding completion percentage Data Rebuilding Operation 11 www RAIDON com tw RAIDON 6 When the rebuilding is fully completed the LCD display screen will again display the following messages Pri HDD OK Sec HDD OK 7 When iR2620 SR2611 is overheating T will be displayed on the lower right hand cor ner of sc
15. y data from one sector to another sector Technically speaking the data will not be lost during the auto rebuilding process However if the original hard drive is detected with bad sectors during the rebuilding process iR2620 SR2611 will make hypothetical duplication instead of treat the bad sectors as hard drive failure Therefore the data stored in the bad sectors could potentially be lost during rebuilding Q Under the mirror mode RAID 1 why does the computer slows down during the data rebuilding process Or why does the data rebuilding process slows down when the data is being processed If the iIR2620 SR2611 system is executing data rebuilding simultaneously while the computer system is saving the data the auto rebuilding process and the saving process will take longer than normal time This is because the iR2620 SR2611 must divide it s resource between the normal system operation and the data rebuilding process However the priority for the iR2620 SR2611 is to maintain the proper system operations Therefore the data rebuilding speed will be extremely slow until the system finished with the data saving operations Other Possible Situations Q The Buzzer will not stop when the iR2620 SR2611 is in operation A Please check whether the readings on the LCD display are normal or if there is a hard drive failure Please also pay attention to any other symbols displayed in the LCD display For example if the F sym